Power System Equipment
Uses:To connect pilot rope lengths or pulling rope lengths and to pass over the puller or tensioner bull wheels.
Notes:“d" refers to the diameter of pin
Item number
Model
Main size(mm)
Rated Load (kN)
Weight (kg)
A
B
..
$8.86
Uses: Apply to erecting pylon sagging operation in line construction.
Item number
09121
09123
Model
JJQ-30-B
JJQ-50-B
Power (hp)
5.5
9
Engine model
Honda GX160
Honda GX270
Speed (rpm)..
$3,010.42
Overview:
PCS-985 generator-transformer unit protection can be applied for turbo-dynamo, gas-turbine, hydro, pumped storage and nuclear power generator with different connection modes. It supports conventional CT/VT and ECT/EVT, and provides interfaces for power plant automation.
For medium to..
$1.00
General
Application: single-column single-arm vertical fold type three-phase AC 50Hz outdoor HV electrical apparatus, for switching under no-load condition and
electrical disconnection between electrical apparatus and live circuit in rated voltage 252kV power system.
Standard: lEC 62271-102..
$15,500.00
GW23-252 Outdoor AC Disconnector Of Horizontal Double-column & Single-arm Flexible Fold Type (252kV)
General
Application: double-column horizontal fold type three-phase AC 50Hz outdoor HV electrical apparatus, for switching under off-load condition and
electrical disconnection between electricalapparatus and live circuit in rated voltage 220kV power system.
Standard: lEC 62271-102.
..
$19,500.00
General
Application: three-phase AC 50Hz outdoor HV electrical apparatus, for switching under noload condition and electrical disconnecting between electrical apparatus and live circuit in rated voltage 35~220kV power system
Standard: IEC 62271-102
Type Designation
Working Condi..
$13,700.00
General
Application: three-phase AC 50Hz outdoor HV electrical apparatus, for switching under no-load condition and electrical disconnecting between electrical
apparatus under repairing and live HV circuit in rated voltage 110kV power system.
Standard: lEC 62271-102.
Type Designatio..
$3,100.00
General
Application: three-phase AC 50Hz outdoor HV electrical apparatus, for switching under no-load condition and electrical disconnecting between electrical
apparatus under repairing and live Hv circuit in rated voltage 220kV power system.
Standard: lEC 62271-102.
Type Designatio..
$13,100.00
1. General
1.1 Main Feature
Dry-type transformer mainly consists of core and windings, it doesn't immerse in insulating liquide. Our dry-type transformer designs according to lEC
standards and China national standards.
With no leakage of oil and gas, security, environmental protection, ..
$1,250.00
Uses: Fixed on the ground .pushing winch handspike manually.
Notes: Users should provide the handspike themselves.
Hand Crank Winch:
Item number
09182
09193
Model
SJB
SJ5
Rated pull force(kN)
5
5
Struct..
$446.25
Head Boards for Two Bundle Conductors
Notes: Can be customized according to the specification of other stringing blocks.
Item number
Model
Rated load (kN)
Applicable stringing block sheave width(mm)
Weight (kg)
Feature
..
$212.50
Uses:They are the primary connecting link in all manner of rigging systems, fromboats and ships to industrial crane rigging, as they allow different riggingsubsets to be connected or disconnected quickly
Item number
Model
Main size (mm)
..
$3.90
Our tractor puller adopts self driving way, which is mostly applied in stringing works. It is suitable for pulling, assembling and tensioning of overhead conductor and OPGW. This machine is a modified product, which comes from the 300 type tractor. It is small and exquisite, providing great mobility..
$28,333.34
General
Ratings: system voltage 3.6~12kV, rated current up to 3150A, AC 50/60Hz.
Application: applicable for power receiving and distribution and for control, protection and measurement of circuit.
Standards: IEC 62271-200
Type Designation
Working Condition
Ambient air tem..
$0.00
General
Ratings: system voltage 3.6~12kV, rated current up to 3150A, AC 50/60Hz.
Application: applicable for power receiving and distribution and for control, protection and measurement of circuit.
Standards: IEC 62271-200
Type Designation
Working Condition
Ambient air tem..
$0.00
General
1.1 Ratings: system voltage 24kV, rated current up to 1250A, AC 50/60Hz.
1.2 Application: applicable for power receiving and distribution of power plant and substations for control, protection and measurement.
1.3 Standards: IEC 62271-200
Type Designation
Working Cond..
$0.00
The central stainless steel tube is surrounded by double layers of aluminium clad steel wires(ACS),the inner layer aluminium clad steel wires are compressed,the outer layer aluminium clad steel wires are all compressed or all round.
Characteristic and Application
Compressing..
$200.00
General
Application: three-pole AC 50Hz outdoor HV electrical apparatus, for control and protection of 110kV power system as well as communicating with circuit
breaker.
Standard: lEC 62271-100.
Type Designation
Working condition
1. Daily temperature variation: ≤25℃
..
$2,500.00
General
Application: three-phase AC 50Hz outdoor HV electrical apparatus with CT14 spring operating mechanism, for control and protection of 35kV
transmission and distribution system as well as communicating with circuit breaker and open/close capacitor group.Standard: lEC 62271-100.
Stand..
$2,500.00
Uses:To connect and grip various steel core Aluminium stranded wires in releasingwires and can pass through various releasing wire block and tensioning wheel.
Item number
Model
Applicable conductor
Load(kN)
Single head
Double h..
$48.88
Uses: Suitable for earth wire construction (including OPGW)
Notes: 1. Please note “A” or “B” while purchasing.
2.Choose the hexagonal die base on the D dimension
Item number
Model
Rated load (kN)
Main dimension (mm)
Applicab..
$20.19
The Aluminium tube is surrounded by single or double layers of aluminium clad steel wires(ACS) or mix ACS wires and aluminium alloy wires.
Characteristic and Application
Replacing one or several wires of the traditional conductor with stainless steel tube and strand the tube..
$200.00
Overview:
The PCS-902 provides comprehensive protection and control solutions for transmission lines with high-speed sub-cycle distance element. The PCS-902 is intended for application on overhead lines and underground cables with diverse voltage levels. These include series compensated, double- ..
$1.00
Overview:
PCS-902S line distance relay integrates main and back-up protection functions, which is designed for overhead line, cables and hybrid transmission lines of various voltage levels and provides comprehensive protection and control solutions. With its flexibility and the powerful PCS-Stud..
$1.00
Overview:
The PCS-915IC centralized busbar relay provides comprehensive protection solution for various arrangements of all voltage levels. The default busbar arrangements include single busbar with/without section, double busbar with/without section, double busbar with transfer bus, breaker-and-..
$1.00
Overview:
The PCS-915ID distributed busbar protection is used for protecting and monitoring various busbar arrangement with all voltage levels, including single busbar with/without section, double busbar with/without sections, double busbar with transfer bus, breaker-and-a-half arrangement and ri..
$1.00
Overview:
PCS-915SC centralized busbar relay integrates busbar differential protection, bus coupler/section protection (includes overcurrent protection, switch-onto-fault protection, dead zone fault protection, dual CTs BC/BS dead zone differential protection and breaker failure protection), feed..
$1.00
Overview:
PCS-915SD distributed busbar relay integrates busbar differential protection, bus coupler/section protection (includes overcurrent protection, switch-onto-fault protection, dead zone fault protection, dual CTs BC/BS dead zone differential protection and breaker failure protection) and f..
$1.00
Overview:
The PCS-921 numerical relay provides protection for circuit breakers, which includes breaker failure protection, pole discrepancy protection, dead zone protection, phase/ negative sequence overcurrent protection, earth-fault protection, overvoltage protection, undervoltage protection, f..
$1.00
Overview:
PCS-921S breaker failure relay integrates various protection functions, which is designed for the single- or three-pole circuit breaker on all voltage levels and provides comprehensive protection and control solutions. With its flexibility and the powerful PCS-Studio configuration tool,..
$1.00
Overview:
The PCS-931 relay provides full-scheme current differential and distance protection solutions for transmission lines with high- speed sub-cycle distance element. As well, the pilot scheme of distance protection and earth fault protection are integrated to provide a complete protection s..
$10,215.00
Overview:
The PCS-9611 relay is a protection, control and monitoring unit for various applications (such as overhead line, underground cable and transformer etc.) on solidly ground, impedance grounded, Peterson coil grounded and ungrounded system. The PCS-9611 features a high performance function..
$2,360.00